Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	35
Date	08/12/14
Start Time	10:29:06
Diameter Midpoint
 10.9	621.594
 11.3	7163.87
 11.8	57364.9
 12.2	79772.6
 12.6	104813
 13.1	127981
 13.6	159236
 14.1	197439
 14.6	232931
 15.1	273744
 15.7	317973
 16.3	367756
 16.8	418292
 17.5	471271
 18.1	524106
 18.8	575628
 19.5	633651
 20.2	692890
 20.9	732001
 21.7	781059
 22.5	829851
 23.3	866015
 24.1	897903
 25.0	928157
 25.9	947337
 26.9	970968
 27.9	962263
 28.9	962873
 30.0	933560
 31.1	895793
 32.2	860742
 33.4	789257
 34.6	714862
 35.9	633297
 37.2	552756
 38.5	470680
 40.0	394772
 41.4	318966
 42.9	252604
 44.5	195335
 46.1	145223
 47.8	106605
 49.6	75433
 51.4	51942.3
 53.3	34828.2
 55.2	23093.6
 57.3	15184.1
 59.4	9882.48
 61.5	6215.53
 63.8	3970.63
 66.1	2430.97
 68.5	1571.46
 71.0	1047.08
 73.7	694.457
 76.4	436.292
 79.1	341.841
 82.0	284.143
 85.1	218.066
 88.2	220.565
 91.4	172.393
 94.7	168.167
 98.2	185.971
101.8	139.315
105.5	129.513
109.4	128.271
113.4	123.129
117.6	122.561
121.9	102.598
126.3	96.1326
131.0	82.6576
135.8	77.4757
140.7	115.229
145.9	116.326
151.2	100.181
156.8	134.667
162.5	104.748
168.5	83.0934
174.7	82.4792
181.1	85.9965
187.7	79.7185
194.6	49.5277
201.7	85.9128
209.1	92.6701
216.7	54.9083
224.7	67.0633
232.9	61.1332
241.4	65.5789
250.3	37.6226
259.5	54.5594
269.0	51.9455
278.8	56.5882
289.0	27.7361
299.6	31.3484
310.6	47.2525
322.0	38.7192
333.8	33.1387
346.0	36.3049
358.7	28.5082
371.8	37.2847
385.4	29.8118
399.5	34.332
414.2	40.3937
429.4	14.4946
445.1	7.36216
461.4	3.4333
478.3	11.4087
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1803
High Voltage	9848.28
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	26.0102
Mean(nm)	26.8514
Geo. Mean(nm)	25.6278
Mode(nm)	26.896
Geo. Std. Dev.	1.35913
Total Concentration(#/cm)	2.16168e+007
Comment	